Selection & Specification

Casing Drift vs ID: Check Downhole Tool Clearance

By OILFIELD RFQ SOURCING3 min read
casing driftcasing IDconnection IDtool clearance9-5/8 in casingTenarisHydril

Start with the reason for the dimension

Use nominal pipe ID for a pipe-body volume calculation. Use the specified drift and the documented restrictions for a passage assessment. A drift is a gauge acceptance condition; it is not a measurement of the smallest opening at every point in a made-up, installed string. A nominal connection ID is also not a guarantee of field clearance.

Five entries to keep separate

EvidenceWhat it answers
Pipe-body nominal IDWhat cylindrical diameter is the starting point for volume?
Body drift diameter and gauge lengthWhat gauge condition was specified for this casing, and what does the traceable inspection record confirm?
Connection bore drawingIs there a local constriction or profile at a particular connection?
Other path restrictionsWhich wellhead bore, landing profile, shoe, accessory or already installed component governs the route?
Running assembly envelopeWhat is the largest OD in the run configuration, including couplings, sleeves or protectors, and over what rigid length?

Same casing weight, different connection bores

The TenarisHydril Wedge 563 brochure and TenarisHydril Blue brochure each list these 9-5/8 in rows. Values below are the published dimensional fields in inches; they apply to the named connection configurations, not to every casing at that weight.

9-5/8 in configurationBody IDListed body driftConnection ID
Wedge 563, 36.00 lb/ft8.921 in8.765 in8.871 in
Wedge 563, 40.00 lb/ft8.835 in8.679 in8.835 in
Blue, 36.00 lb/ft8.921 in8.765 in8.829 in
Blue, 40.00 lb/ft8.835 in8.679 in8.781 in

The 40.00 lb/ft connections differ in listed nominal connection ID by 0.054 in. Their pipe-body input for a volume calculation is identical. Neither number overrides the drift basis or the accessory path. Confirm any alternate drift separately against the exact quote and the corresponding inspection record.

Screen a drawing, not a trade size

An illustrative running OD of 8.700 in is 0.135 in smaller than the 8.835 in nominal body ID above, but it is 0.021 in larger than the listed 8.679 in drift gauge. Standard drift documentation does not demonstrate passage of that OD. This arithmetic is not a rejection or an approval of any specific installation. Where there is a restriction, ask for a dimensional stack-up including tolerance, rigid length, trajectory, and condition of the installed hardware.

Use the OD/ID volume guide for geometry, or the liner hanger passage example if a wellhead or running assembly is the limiting interface.

RFQ checklist for drift and clearance

  • Specify casing OD, weight, grade, exact connection and make-up revision by depth interval.
  • Request the agreed drift diameter, gauge length and inspection evidence. Identify any change from the listed basis explicitly.
  • Attach the minimum-ID drawing and revisions for each suspected restriction, and the maximum-OD and rigid-length drawings for the complete running assembly.
  • Document who signs off the dimensional margin and who is responsible for the ability to run and recover the tool.

Compare the OCTG casing and tubing reference and supplier drawings before releasing the order.

Authoritative references