Selection & Specification

Liner Hanger Selection: Running OD vs Installed Bore

By OILFIELD RFQ SOURCING3 min read
liner hanger running ODliner hanger borewellhead restrictionVersaFlexliner hangerpassage clearance

Ask for two envelopes, not just the liner size

A liner hanger must reach depth as part of a running assembly. After setting and releasing the running tool, the installed envelope must meet completion and intervention requirements. One dimension cannot establish both. Request the drawings with the installation state and governing tolerance stated for each value.

QuestionDrawing or evidence to request
Will the running string reach depth?Maximum OD and rigid length of the full run configuration, checked against minimum documented IDs on the route, including wellhead and already installed components
What passage is left after the tool is released?Minimum bore drawing for the installed hanger, seal bore or tieback profile, with suitable gauge and acceptance basis
Can it suspend and seal in the chosen casing?Qualification matrix for the proposed parent casing weight, grade and connection, with relevant combined loads, differential pressure and temperature
Is the package complete?A tagged list separating installed components, retrievable tooling, spares and excluded interfaces

Published example: wellhead passage on a 16 × 22 in system

A Halliburton VersaFlex Big Bore case reports a maximum hanger OD of 18.400 in and a 18.448 in minimum subsea wellhead ID for a specific installation. The difference, 0.048 in, is a diameter difference; the centered radial difference is 0.024 in before other effects. This is not the installed hanger bore, a design allowance, or a universal pass criterion. The well-design team evaluated that individual route. Neither number can be carried over to another wellhead, running assembly, or tool size.

A second Halliburton case identifies a different parent casing, 10-1/8 in at 81 lb/ft, paired with a 7-3/4 in liner and an XtremeGrip system. The casing wall basis was part of the selection. This example does not set the allowed weight range or prove a load rating for another configuration.

What to do with an incomplete quote

If the quote says only “7-in liner,” ask the supplier to identify the parent-casing row and send the two drawings. Mark any undisclosed dimension as unresolved, not “standard.” A gauge report for only the tubular section does not replace the assembly-envelope or wellhead drawing. The casing drift and tool clearance guide distinguishes nominal pipe ID from the gauge and connection fields.

Liner hanger RFQ checklist

Attach the parent casing and liner tally, drawing revisions, restriction register, service environment, load cases and setting depth. Request installed bore, running OD/length, hanger and seal validation basis, and a tooling responsibility list. Keep case data separate from supplier-guaranteed values on the comparison sheet. For equipment scope and the two published cases, see the liner hanger systems reference.

Authoritative references