Home/Resources/BOP Control Selection: Pressure Ratings and Usable Fluid

Selection & Specification

BOP Control Selection: Pressure Ratings and Usable Fluid

By OILFIELD RFQ SOURCING•October 23, 2026•4 min read
BOP control unitsannular BOPusable accumulator fluidhydraulic pressuretechnical bid review

On this page

  1. One pressure column is not enough
  2. Separate the three document fields
  3. Usable fluid is not the bottle size
  4. Function count is a screening field
  5. Treat certification as an order-specific question
  6. A clearer RFQ package

View the model-specific values, conditions and sources

One pressure column is not enough

A BOP and its control unit can each have more than one pressure-related entry. Putting all of them in a single quotation column called "pressure rating" obscures which boundary the number describes. Before comparing offers, name the equipment, identify the pressure domain and retain the manufacturer's original label.

This guide concerns purchasing documents, not well-control operation, accumulator charging, pressure testing or maintenance. Those activities require qualified personnel and the applicable controlled procedures. The examples below do not approve a stack or specify operating setpoints.

Separate the three document fields

The Rongsheng FH28-70 annular reference lists a wellbore-side working-pressure rating and a distinct rated hydraulic-control working pressure. The FKQ240-3 surface control-unit reference has its own system working-pressure entry. The values and source locations are reproduced in the model-reference table below.

Field in a bid tabWhat to preserveQuestion that remains
BOP rated working pressureExact preventer model and wellbore-side labelWhich material and temperature configuration is covered?
BOP hydraulic-control ratingExact control-side label and device modelWhat do the controlled operating documents require?
Control-unit system pressureNamed unit and circuit contextHow are the regulated circuits matched to each device?

Matching two numbers is not a selection method. A pressure value can describe a rated limit, a system specification or an operating requirement. Their labels and documentary scope determine whether the comparison is meaningful.

Usable fluid is not the bottle size

The control-unit source explicitly identifies nominal usable accumulator fluid. Rewriting that field as total accumulator capacity loses information. Geometric volume and fluid available over a defined operating interval are different quantities.

For a bid review, ask the proposed manufacturer to supply its usable-fluid calculation with the relevant pressure, temperature and precharge assumptions. Also request the actual controlled devices and their documented fluid demands. This guide intentionally provides no universal conversion from bottle volume to usable fluid and no substitute for a stack-specific sizing calculation.

Function count is a screening field

A catalogue function count can help identify the intended control scope, but an equal count does not prove that two stacks require equal fluid or meet the same performance criteria. Keep the named devices, interfaces and required functions visible in the RFQ.

An assumed example illustrates the document issue: two bids each list the same number of functions, but only one identifies the controlled models and provides a calculation basis. The first action is to obtain the missing basis from the other bidder, not to declare either bid technically acceptable. This is a document-review scenario, not a report of a field installation.

Treat certification as an order-specific question

The Rongsheng control-unit page requests the BOP-stack configuration and parameters for selection calculations when API-monogram supply is required. That instruction does not establish current licence coverage for every model or prove that an offered unit is already certified.

Record the required standard and edition, manufacturer identity, product scope and documentary evidence separately. Use the standard-edition checklist for the version check; it does not replace verification of an offered product's actual scope.

A clearer RFQ package

Attach the approved stack schematic, named equipment list, required control functions, site utilities, interface drawings and acceptance requirements. Ask the bidder to return its controlled circuit drawings, sizing basis, deviations and proposed test documentation.

In the comparison sheet, keep columns for the requirement, offered configuration, document revision, open clarification and technical disposition. A missing assumption should remain visible until resolved. Carry the reviewed requirements into the RFQ Builder; attach private project files through the inquiry form rather than publishing them as source material.

Referenced model data

ModelParameterReference valueConditions and source
FH28-70Nominal bore279.4 mm

FH28-70 D-type spherical-element annular BOP. This row does not establish interchangeability with another model of the same bore.

Model table, FH28-70 row, bore

Checked 2026-10-23

FH28-70Rated working pressure69 MPa

FH28-70 wellbore-side pressure rating. Temperature class and packing-element material are not bound to this row. Not the hydraulic-control pressure.

Model table, FH28-70 row, rated working pressure

Checked 2026-10-23

FH28-70Rated hydraulic-control working pressure13.8 MPa

FH28-70 hydraulic rating, separate from wellbore pressure. This is not an instruction to apply that pressure in every operating condition; use the model-specific operating manual.

Model table, FH28-70 row, rated hydraulic-control working pressure

Checked 2026-10-23

FKQ240-3Number of controlled functions3 objects

FKQ240-3 standard table configuration. The actual BOP stack and closing-fluid demand still require selection calculations; equal function counts do not prove compatibility.

Technical table, FKQ240-3 row, control objects

Checked 2026-10-23

FKQ240-3Nominal usable accumulator fluid120 L

FKQ240-3. This is usable fluid, not geometric vessel capacity. Precharge and minimum working-pressure assumptions are not defined in this row and must be confirmed.

Technical table, FKQ240-3 row, nominal usable fluid

Checked 2026-10-23

FKQ240-3System working pressure21 MPa

FKQ240-3 standard configuration. Control-circuit regulation and the controlled equipment's limits must be matched separately; do not apply this value directly to every annular BOP.

Technical table, FKQ240-3 row, system pressure

Checked 2026-10-23

Authoritative references

  • Rongsheng D-type annular BOP model tablechecked 2026-10-23
  • Rongsheng surface BOP control-unit model tablechecked 2026-10-23

On this page

  1. One pressure column is not enough
  2. Separate the three document fields
  3. Usable fluid is not the bottle size
  4. Function count is a screening field
  5. Treat certification as an order-specific question
  6. A clearer RFQ package

Related Products

BOP Accumulator and Control UnitsRam and Annular Blowout PreventersCoiled Tubing Control Cabins and Power Packs

Preparing a Technical RFQ?

Send the specification, quantity, destination and target price so the open technical points can be identified.

Contact Us

RFQ preparation tools

Structured RFQ BuilderEquipment ParametersAPI Standards NavigatorProcurement Glossary

More in Selection & Specification

Gas Generator Bid Review: Fuel Basis Is Not Electrical Output

3 min read

Power Tong Capacity Is Not Connection Make-Up Torque

3 min read

Drilling Jar Review: Tensile Rating and Jarring Force Are Different Fields

3 min read

OILFIELD RFQ

Technical references, practical calculations and structured equipment requests for the oilfield industry.

Equipment

  • Wellhead & Pressure Control
  • Drilling & Downhole Tools
  • Mud Pump & Rig Spares
  • Sourcing & Export

Resources

  • Buyer Guides
  • Calculators & RFQ Builder
  • Equipment Reference
  • API Standards Navigator
  • FAQ
  • Procurement Glossary
  • Solutions
  • About Us
  • Contact

Contact

  • Submit RFQ online
  • China

© 2026 OILFIELD RFQ SOURCING. All rights reserved.

Privacy Policy|Terms of Service