Selection & Specification
BOP Control Selection: Pressure Ratings and Usable Fluid
View the model-specific values, conditions and sources
One pressure column is not enough
A BOP and its control unit can each have more than one pressure-related entry. Putting all of them in a single quotation column called "pressure rating" obscures which boundary the number describes. Before comparing offers, name the equipment, identify the pressure domain and retain the manufacturer's original label.
This guide concerns purchasing documents, not well-control operation, accumulator charging, pressure testing or maintenance. Those activities require qualified personnel and the applicable controlled procedures. The examples below do not approve a stack or specify operating setpoints.
Separate the three document fields
The Rongsheng FH28-70 annular reference lists a wellbore-side working-pressure rating and a distinct rated hydraulic-control working pressure. The FKQ240-3 surface control-unit reference has its own system working-pressure entry. The values and source locations are reproduced in the model-reference table below.
| Field in a bid tab | What to preserve | Question that remains |
|---|---|---|
| BOP rated working pressure | Exact preventer model and wellbore-side label | Which material and temperature configuration is covered? |
| BOP hydraulic-control rating | Exact control-side label and device model | What do the controlled operating documents require? |
| Control-unit system pressure | Named unit and circuit context | How are the regulated circuits matched to each device? |
Matching two numbers is not a selection method. A pressure value can describe a rated limit, a system specification or an operating requirement. Their labels and documentary scope determine whether the comparison is meaningful.
Usable fluid is not the bottle size
The control-unit source explicitly identifies nominal usable accumulator fluid. Rewriting that field as total accumulator capacity loses information. Geometric volume and fluid available over a defined operating interval are different quantities.
For a bid review, ask the proposed manufacturer to supply its usable-fluid calculation with the relevant pressure, temperature and precharge assumptions. Also request the actual controlled devices and their documented fluid demands. This guide intentionally provides no universal conversion from bottle volume to usable fluid and no substitute for a stack-specific sizing calculation.
Function count is a screening field
A catalogue function count can help identify the intended control scope, but an equal count does not prove that two stacks require equal fluid or meet the same performance criteria. Keep the named devices, interfaces and required functions visible in the RFQ.
An assumed example illustrates the document issue: two bids each list the same number of functions, but only one identifies the controlled models and provides a calculation basis. The first action is to obtain the missing basis from the other bidder, not to declare either bid technically acceptable. This is a document-review scenario, not a report of a field installation.
Treat certification as an order-specific question
The Rongsheng control-unit page requests the BOP-stack configuration and parameters for selection calculations when API-monogram supply is required. That instruction does not establish current licence coverage for every model or prove that an offered unit is already certified.
Record the required standard and edition, manufacturer identity, product scope and documentary evidence separately. Use the standard-edition checklist for the version check; it does not replace verification of an offered product's actual scope.
A clearer RFQ package
Attach the approved stack schematic, named equipment list, required control functions, site utilities, interface drawings and acceptance requirements. Ask the bidder to return its controlled circuit drawings, sizing basis, deviations and proposed test documentation.
In the comparison sheet, keep columns for the requirement, offered configuration, document revision, open clarification and technical disposition. A missing assumption should remain visible until resolved. Carry the reviewed requirements into the RFQ Builder; attach private project files through the inquiry form rather than publishing them as source material.
Referenced model data
| Model | Parameter | Reference value | Conditions and source |
|---|---|---|---|
| FH28-70 | Nominal bore | 279.4 mm | FH28-70 D-type spherical-element annular BOP. This row does not establish interchangeability with another model of the same bore. Model table, FH28-70 row, boreChecked 2026-10-23 |
| FH28-70 | Rated working pressure | 69 MPa | FH28-70 wellbore-side pressure rating. Temperature class and packing-element material are not bound to this row. Not the hydraulic-control pressure. Model table, FH28-70 row, rated working pressureChecked 2026-10-23 |
| FH28-70 | Rated hydraulic-control working pressure | 13.8 MPa | FH28-70 hydraulic rating, separate from wellbore pressure. This is not an instruction to apply that pressure in every operating condition; use the model-specific operating manual. Model table, FH28-70 row, rated hydraulic-control working pressureChecked 2026-10-23 |
| FKQ240-3 | Number of controlled functions | 3 objects | FKQ240-3 standard table configuration. The actual BOP stack and closing-fluid demand still require selection calculations; equal function counts do not prove compatibility. Technical table, FKQ240-3 row, control objectsChecked 2026-10-23 |
| FKQ240-3 | Nominal usable accumulator fluid | 120 L | FKQ240-3. This is usable fluid, not geometric vessel capacity. Precharge and minimum working-pressure assumptions are not defined in this row and must be confirmed. Technical table, FKQ240-3 row, nominal usable fluidChecked 2026-10-23 |
| FKQ240-3 | System working pressure | 21 MPa | FKQ240-3 standard configuration. Control-circuit regulation and the controlled equipment's limits must be matched separately; do not apply this value directly to every annular BOP. Technical table, FKQ240-3 row, system pressureChecked 2026-10-23 |
Authoritative references
- Rongsheng D-type annular BOP model tablechecked 2026-10-23
- Rongsheng surface BOP control-unit model tablechecked 2026-10-23