AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.
OCTG & Tubular Handling
Drill Pipe Configuration References
Compare two TSC drill-pipe configurations with NEW pipe-body dimensions, distinct heading-weight designations and connection-specific RFQ questions.
- Documented model references
- TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2 · TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2
- Parameters, conditions and sources
Source-bound technical references
Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.
- TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2NEW pipe-body outside diameter
- 3.500 in
TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit.
Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. O.D.Revision Revision 9 · Document 2025-05-22 · Checked 2026-10-23
- TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2NEW pipe-body nominal wall
- 0.368 in
TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit.
Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. WallRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23
- TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2Header pipe-weight designation
- 13.30 lb/ft
TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit.
Page 1, top configuration heading; not the approximate assembly-weight tableRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23
- TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2NEW pipe-body outside diameter
- 5.000 in
TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit.
Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. O.D.Revision Revision 9 · Document 2025-05-22 · Checked 2026-10-23
- TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2NEW pipe-body nominal wall
- 0.362 in
TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit.
Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. WallRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23
- TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2Header pipe-weight designation
- 19.50 lb/ft
TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit.
Page 1, top configuration heading; not the approximate assembly-weight tableRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23
| Model | Parameter | Reference value | Conditions and source |
|---|---|---|---|
| TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2 | NEW pipe-body outside diameter | 3.500 in | TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit. Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. O.D.Revision Revision 9 · Document 2025-05-22 · Checked 2026-10-23 |
| TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2 | NEW pipe-body nominal wall | 0.368 in | TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit. Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. WallRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23 |
| TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2 | Header pipe-weight designation | 13.30 lb/ft | TSC TSDS38 / 3-1/2 in EU / 13.30 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit. Page 1, top configuration heading; not the approximate assembly-weight tableRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23 |
| TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2 | NEW pipe-body outside diameter | 5.000 in | TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit. Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. O.D.Revision Revision 9 · Document 2025-05-22 · Checked 2026-10-23 |
| TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2 | NEW pipe-body nominal wall | 0.362 in | TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit. Page 1, PIPE BODY DATA, NEW (100% RBW), Nom. WallRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23 |
| TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2 | Header pipe-weight designation | 19.50 lb/ft | TSC TSDS50 / 5 in IEU / 19.50 lb/ft / Grade S / Range 2; dimensions refer only to the NEW (100% RBW) pipe-body column. Grade S is retained as printed. Header pipe-weight designation is not the approximate uncoated assembly weight, whose separate table uses TSC 95% RBW. Reference configuration, not an operating limit. Page 1, top configuration heading; not the approximate assembly-weight tableRevision Revision 9 · Document 2025-05-22 · Checked 2026-10-23 |
Calculators and selection guide
Use the pipe-body OD for the surrounding annulus and the pipe-body ID for internal volume. Tool joints and upsets can change local geometry; take their dimensions from the exact manufacturer configuration above.
Product overview
Drill pipe starts with a complete configuration
Drill pipe quotations need a pipe-body identity and a connection identity, not merely a diameter. This reference compares two actual TSC Drill Pipe configurations published by Texas Steel Conversion. They are useful starting points for a technical enquiry, not statements of inventory, manufacturer representation or suitability for a particular well. Keep the selected manufacturer's configuration and the buyer's drilling programme separate until the responsible engineer has reviewed their relationship.
Two source-bound reference configurations
The TSC TSDS38 sheet and TSC TSDS50 sheet both carry Revision 9 dated May 22, 2025. The following dimensions come from each sheet's NEW, 100% remaining-body-wall column. Weight is the pipe-weight designation in the heading, not the separate approximate assembly weight.
| Printed configuration | Body OD, in | Nominal wall, in | Heading weight, lb/ft |
|---|---|---|---|
| TSDS38, 3-1/2 in EU, Grade S, Range 2 | 3.500 | 0.368 | 13.30 |
| TSDS50, 5 in IEU, Grade S, Range 2 | 5.000 | 0.362 | 19.50 |
Grade S is retained exactly as printed. The configuration names above identify real catalogue rows; they are not newly assigned stock codes. Neither row is an envelope covering all pipe with the same nominal diameter.
Keep three different bases visible
First, dimensional condition matters. A NEW column and a PREMIUM column are not interchangeable descriptions of one offered item. Request the condition of the quoted pipe and the inspection record relevant to that condition. Do not fill an incomplete new-pipe quotation using values taken from the premium column.
Second, the heading weight and the approximate assembly-weight table answer different questions. The latter uses a stated TSC 95% remaining-body-wall basis for an uncoated assembly. It should not silently replace the heading designation in a tubular schedule. Ask the bidder which basis supports any shipping estimate and which designation identifies the ordered pipe.
Third, a connection label does not replace a complete dimensional drawing. Record the specified tool joint, pin and box arrangement, applicable drawing revision and any required connection documentation. This page does not convert the reference dimensions into torque settings, load limits or an approved drill-string design.
Compare offers by identity before price
A useful bid comparison keeps the purchaser's requested configuration beside the offered configuration. If a bidder changes upset type, weight designation, connection or condition, require a separate deviation line. An offer that preserves the pipe diameter but changes one of those fields is not automatically equivalent.
For replacement purchases, identify whether the requirement is additional matching pipe, replacement assemblies or investigation of an existing string. Supply available mill records and connection identification rather than asking a vendor to infer the full specification from a rack photograph. A missing document should remain an open question, not become an assumed grade or wall.
Define the purchasing boundary
Specify quantity, required length arrangement, inspection scope, marking and traceability requirements, coating or preservation needs, and delivery destination. Request confirmation of the offered configuration and its document references before comparing commercial terms. Catalogue data does not demonstrate current stock, certification of an offered lot or authority to sell for the named manufacturer.
The drill-pipe configuration comparison guide provides a document-level decision table for separating body, tool-joint and assembly information. Start a drill-pipe RFQ with the selected row and all unresolved deviations. The existing image is an AI-generated tubular-category reference, not a photograph of either TSC configuration.
Technical reference trail
These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.
Frequently Asked Questions
Can the TSC heading weight replace the approximate assembly weight?
No. The 13.30 and 19.50 lb/ft figures identify the respective pipe configurations in the headings. The separate uncoated assembly-weight table uses a TSC 95% remaining-body-wall basis. Specify which basis is needed rather than treating the two as identical.
Which condition supports the TSDS38 and TSDS50 body dimensions shown here?
Only the NEW (100% remaining-body-wall) column. The PREMIUM column is a separate condition and must not supply missing values for a new-pipe offer. Grade S is retained as printed in the current sheets.
Submit RFQ for Drill Pipe Configuration References
Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.
Technical and RFQ References
Check common units, standards and purchasing terminology, then build a structured request for this equipment.
Related Products

OCTG Casing and Tubing
OCTG casing and tubing with the dimensions an RFQ needs: OD, nominal weight, wall, ID and drift. A 7 in casing example shows how weight changes ID and internal capacity at the same OD.

Drilling Tools and BHA Components
Drilling Tools and BHA Components for drillstring assembly, directional drilling, impact release, hole conditioning and fishing operations, with quotation fields for tool type, outside diameter, inside diameter, connection, fishing-neck size, tensile/torsional requirement, operating environment and requested inspection documents.

Drill Collars and Heavy-Weight Drill Pipe
Separate NOV Standard and Spiral-Wate HWDP configurations from drill-collar recess references, with clear weight bases and drawing-level purchasing questions.
Related Technical Articles
Drill Pipe Selection: TSDS38 and TSDS50 Body, Joint and Weight
Separate pipe-body condition, tool-joint identity and assembly-weight basis with a practical decision table for inconsistent drill-pipe quotations.
Drilling Tools Supplier Selection Guide
A compact guide to sourcing drilling stabilizers, drilling jars, drill collars, subs, reamers, and downhole tools.
Pipe Capacity, Annular Volume and Displacement: Which OD or ID to Use
Internal capacity, annular capacity, open-end and closed-end displacement each use a different diameter. One worked 5 in drill pipe and 9-5/8 in casing example shows all four and how they add up.