Instrumentation & Automation
Oilfield Flow Meters
Oilfield Flow Meters for wellsite, production-facility and process-skid pressure, differential pressure, temperature, flow and level measurement, with quotation fields for measured variable, calibrated range, accuracy, process connection, wetted materials, temperature, output protocol, power supply, enclosure rating and hazardous-area certification required by the project.
RFQ selection reference
Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.
| Parameter | Reference value | Notes |
|---|---|---|
| Measurement range | Application-specific calibrated span | State normal, minimum and maximum values |
| Signal and protocol | 4-20 mA, HART or digital as specified | Confirm host-system compatibility |
| Process and area | Connection, wetted material and area rating | Certification must match the destination project |
Product overview
Product scope
Oilfield Flow Meters is presented as a quotation-ready equipment family for wellsite, production-facility and process-skid pressure, differential pressure, temperature, flow and level measurement. The page is intended to help buyers define a technically comparable request, not to promise one fixed model or universal specification. Final configuration, dimensional fit, pressure or load rating, material, documentation and compliance must be confirmed against the selected manufacturer's signed datasheet and the purchase specification.
Selection basis
The main selection fields are measured variable, calibrated range, accuracy, process connection, wetted materials, temperature, output protocol, power supply, enclosure rating and hazardous-area certification required by the project. For replacement work, include the installed equipment maker, model, serial number, original part number, clear nameplate photographs and a dimensioned sketch. Similar-looking oilfield parts are frequently non-interchangeable, so appearance alone is not an adequate purchasing reference.
Reference configuration table
The table above lists common RFQ fields rather than guaranteed stock models. Values shown as ranges or options are preliminary screening information. The buyer, supplier and final manufacturer should close every open item during technical clarification before a commercial order is released.
Documents and quality checks
Define the required document package at quotation stage. Typical requests may include a signed datasheet, dimensional drawing, material certificate, pressure or functional test report, NDT report, certificate of conformity, packing list, marking photographs and preservation procedure. Ask for API or other certification only when the specific product and manufacturing facility must hold it; a website reference is not proof of certification.
RFQ checklist
- Product name, equipment model and required quantity
- Operating pressure or load, temperature, media and service environment
- Size, connection, material, tolerance and applicable standard with edition
- Existing part number, nameplate photos, drawings or technical specification
- Required inspection, testing, traceability and third-party witness points
- Delivery destination, Incoterm, requested delivery date and packing method
- Target price or budget range, plus whether technically equivalent alternatives are acceptable
Upload the specification sheet with the inquiry. We will use it to organize the technical comparison and identify clarification points before quotation.
Technical reference trail
These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.
Frequently Asked Questions
What information is needed to quote Oilfield Flow Meters?
Provide measured variable, calibrated range, accuracy, process connection, wetted materials, temperature, output protocol, power supply, enclosure rating and hazardous-area certification required by the project, quantity, destination, delivery target and the required document package. Attach the governing datasheet or drawing whenever one exists.
Are the displayed ranges guaranteed for an order?
No. They are selection references only. The final manufacturer quotation, signed datasheet and purchase specification control the ordered configuration.
Can I upload a specification or replacement-part photographs?
Yes. The RFQ form accepts technical files and photographs. Include a target price when available so unsuitable options can be screened earlier.
Submit RFQ for Oilfield Flow Meters
Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.
Technical and RFQ References
Check common units, standards and purchasing terminology, then build a structured request for this equipment.
Related Products

Oil and Gas Pressure Transmitters
Pressure transmitters for wellheads, process skids and production facilities, with published reference ranges from 5 kPa to 260 MPa and selectable analog or digital outputs.

Differential Pressure Transmitters
Differential pressure transmitters for flow, filter, vessel and level measurement. The cited FD3051S DP family spans 50 Pa to 3 MPa differential; static-pressure options are separate.

Temperature Transmitters, Thermocouples and RTDs
Compare temperature instruments using published FDWB integrated and compact transmitter examples. Specify the sensor type, calibrated span, probe construction and control-system input separately.

Process Level Transmitters
Process level transmitter selection using the FD86T pressure-guided example. Keep water-head range, operating temperature, enclosure protection and electrical interface distinct when preparing a tank or vessel RFQ.