AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.
Instrumentation & Automation
Oil and Gas Pressure Transmitters
Pressure transmitters for wellheads, process skids and production facilities, with published reference ranges from 5 kPa to 260 MPa and selectable analog or digital outputs.
Published family data and RFQ checks
Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.
| Parameter | Reference value | Notes |
|---|---|---|
| Family pressure range | 5 kPa-260 MPa | Select a calibrated span with suitable turndown |
| Accuracy options | 0.25-1.0% full scale | Confirm the option in the signed model code |
| Operating temperature | -20 to 80 degrees C | Process temperature may require an impulse line or seal |
| Output and communication | 4-20 mA or 1-5 VDCRS485, HART or Modbus RTU | Match the host control system |
Model-specific technical reference
FD3051T range is a family envelope
The manufacturer's FD3051T product page describes the selectable family from 5 kPa to 260 MPa and lists 0.25%, 0.5% and 1.0% full-scale accuracy options. These endpoints are not one calibrated span. For each instrument tag, request the full model code, pressure type, calibrated lower and upper range, process connection, wetted materials, output and applicable certificate. The published manufacturer data is not an offer of a specific configuration or evidence of our dealership, stock or supply rights.
Published manufacturer data is a selection reference, not a quotation or evidence of supply availability.
Product overview
Measured pressure and range selection
Pressure transmitters convert gauge, absolute or negative pressure into a control-system signal. A published FD3051T reference family spans low-pressure applications beginning at 5 kPa and high-pressure configurations reaching 260 MPa; those endpoints describe a family range, not one sensor capsule. The RFQ should identify normal pressure, minimum and maximum operating pressure, allowable overpressure and whether vacuum measurement is required.
Accuracy, temperature and signal
Published accuracy options for the referenced family are 0.25%, 0.5% and 1% of full scale, with a stated operating-temperature range of -20 to 80 degrees C. Output choices include 4-20 mA, 1-5 VDC and RS485, while HART and Modbus RTU are listed communication options. The buyer must state the control-system input, loop power, cable entry and whether local indication is needed.
Process connection and environment
A pressure range alone does not define an interchangeable instrument. Include the thread or flange connection, diaphragm and wetted materials, fill fluid, enclosure material, ingress rating, ambient conditions and hazardous-area classification. For sour or corrosive service, attach the process composition and the project material specification instead of selecting by pressure only.
RFQ checklist
Send the instrument datasheet, tag list, calibrated span, alarm or trip duty, quantity and destination with the inquiry. Ask the proposed source to return a signed model code, accuracy statement, dimensional drawing and calibration documentation. IP65 and explosion-protection markings shown on a product page remain configuration claims until the exact ordered model and certificate scope are verified.
Technical reference trail
These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.
Frequently Asked Questions
Does one pressure transmitter cover 5 kPa to 260 MPa?
No. The figures describe the endpoints of a product family. The calibrated capsule, overpressure limit and process connection must be selected for each tag.
Which signal details belong in the RFQ?
State 4-20 mA, voltage or RS485 requirements, HART or Modbus protocol, loop power, display, cable entry and control-system compatibility.
Can an explosion-proof configuration be assumed?
No. Request the exact protection concept, certificate, model coverage, gas group, temperature class and destination acceptance before approval.
Submit RFQ for Oil and Gas Pressure Transmitters
Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.
Technical and RFQ References
Check common units, standards and purchasing terminology, then build a structured request for this equipment.
Related Products

Differential Pressure Transmitters
Differential pressure transmitters for flow, filter, vessel and level measurement. The cited FD3051S DP family spans 50 Pa to 3 MPa differential; static-pressure options are separate.

Needle Valves and Instrument Manifolds
Needle Valves and Instrument Manifolds for instrument isolation, equalization, bleed, calibration and impulse-line service around pressure and differential-pressure instruments, with RFQ fields covering valve or manifold arrangement, port size and thread, pressure and temperature, flow coefficient or orifice, body and trim material, stem tip, packing, mounting pattern, sour service, fire safety and cleanliness requirements.

Oilfield Process Control Systems
Oilfield Process Control Systems for wellsite, production-facility and process-skid pressure, differential pressure, temperature, flow and level measurement, with quotation fields for measured variable, calibrated range, accuracy, process connection, wetted materials, temperature, output protocol, power supply, enclosure rating and hazardous-area certification required by the project.
Related Technical Articles
How to Specify Pressure Transmitters for an Oilfield RFQ
Compare calibrated range, accuracy, output, process connection, wetted materials and installation conditions before requesting a pressure-transmitter quotation.
Pressure Transmitter Range, Accuracy and Output: Datasheet Review
Review the published FD3051T range, accuracy, temperature, output and protocol options, with limits that must be confirmed in the selected datasheet.
How to Specify Differential Pressure Transmitters for an Oilfield RFQ
Define low- and high-side pressure, differential span, static pressure, manifold arrangement, output and impulse-line conditions before quotation.