Selection & Specification
Triplex Mud Pump Liner Size, Pressure and Flow: What You Can Calculate
Choose the reference for your task
| What you need | Where to check | What it cannot tell you |
|---|---|---|
| Theoretical output per stroke or flow at a given speed | Triplex pump output calculator. If you already know bbl/stroke and have a total stroke count, use pump strokes to volume. | Neither establishes a working pressure or confirms fit. |
| Rated performance for a given bore and fluid end | NOV 12-P-160 performance sheet, printed p. 38, liner table and footnotes. Match the installed configuration before using the pressure column. | The optional fluid-end table does not rate a standard fluid end or an undocumented retrofit. |
| Sleeve material and wear considerations | NOV Mission expendables guide, printed pp. 5-7. | Material or a family maximum is not a part-number match or a pump rating. |
| Liner, piston or gasket part number | Start with the matching Mission Databook entry: standard 12-P-160, 12-P-160HP, or 12-P-160 with Mission L fluid end. Then use the liner and piston part-number table for the standard configuration example. | A matching bore, or an HP suffix on a part number, does not establish the fluid-end configuration or approval to substitute. |
Three numbers you can work out, and the ones you cannot
If you know the pump model, the liner bore and the stroke rate, you can estimate the volume per stroke, the flow at that rate, and the hydraulic power the pump would need to deliver a given pressure at that flow. You cannot work out the maximum safe discharge pressure for a liner, the actual delivered flow at your well, or whether a replacement liner or piston fits. Those come from the manufacturer's liner table and the part drawings.
This guide uses the NOV 12-P-160 triplex mud pump specification sheet as a worked reference: a 1,600 hp single-acting triplex with a 12 in stroke, rated at 120 strokes per minute. The figures below are that sheet's published values, used here to explain the method. They are not an offer of a pump or proof of stock.
Step 1: volume per stroke from liner bore and stroke
For a single-acting triplex, theoretical volume per pump stroke is three times the swept volume of one cylinder. With dimensions in inches:
- bbl per stroke = 3 x pi / 4 x liner bore squared x stroke length / 9,702
- US gallons per stroke = bbl per stroke x 42
For a 6 in liner and 12 in stroke this gives 4.406 gal per stroke, which is the value the NOV sheet lists for the 6 in liner. The triplex pump output calculator uses the same equation, so you can reproduce any row of a manufacturer's table and check that you have read the liner and stroke correctly.
Step 2: flow at a stroke rate
Flow is volume per stroke multiplied by strokes per minute. At 120 spm the 6 in liner gives 4.406 x 120 = about 529 gpm. The NOV sheet lists 529 gpm for that liner at 120 spm, and its footnote states the flow figures assume 100% volumetric efficiency.
Actual delivered flow can be lower than the theoretical value. Valve leakage, suction conditions and entrained gas all reduce it, so the calculator applies a separate volumetric efficiency that you enter. Use a measured or documented figure for your pump; an assumed 90% is an example, not a test result.
Step 3: why a smaller liner allows a higher pressure
A pump with fixed input power can trade flow for pressure. Hydraulic horsepower is discharge pressure in psi multiplied by flow in gpm, divided by 1,714. For the 12-P-160 rows at 120 spm, the listed pressure column is for the optional 7,500 psi fluid end only:
| Liner bore | Gal per stroke | Flow at 120 spm | Listed max discharge pressure | Pressure x flow / 1,714 |
|---|---|---|---|---|
| 7 in | 5.997 | 720 gpm | 3,430 psi | about 1,441 hp |
| 6-1/2 in | 5.171 | 621 gpm | 3,980 psi | about 1,442 hp |
| 6 in | 4.406 | 529 gpm | 4,670 psi | about 1,441 hp |
| 5-1/2 in | 3.702 | 444 gpm | 5,555 psi | about 1,439 hp |
| 5 in | 3.060 | 367 gpm | 6,720 psi | about 1,439 hp |
Each row works out to roughly 1,440 hydraulic horsepower, which is the 1,600 hp input rating at the 90% mechanical efficiency the sheet states. The listed pressure for each liner is the pressure that uses the full power at rated speed. That is why the pressure rises as the liner gets smaller.
Step 4: the catalog maximum is not your working pressure
Three limits sit on top of the power calculation, and the lowest one governs.
- Fluid-end pressure rating. The NOV sheet notes that its pressures are for an optional 7,500 psi fluid end and that the standard 12-P-160 is rated for 5,000 psi. Do not read the optional 5-1/2 in and 5 in pressure rows as ratings for the standard fluid end. The quoted standard fluid-end rating is a ceiling, not permission to run a particular assembly at that pressure.
- Consumables and discharge components. Liners, pistons, valves, the discharge manifold and the pulsation dampener each carry their own pressure ratings. A part rated below the liner table value sets a lower limit.
- The duty you need. The table pressure is a maximum at rated speed. The pressure a rig actually runs at is set by the circulating system, not by the pump table, and the stroke rate is often below 120 spm.
A catalog row documents the stated combination of liner, speed, efficiency and configuration. It is not a live measurement. It does not answer the question of what pressure is safe for your installed equipment.
RFQ checklist for a pump or liner request
Include these items when you request a quote, so the supplier can check the duty and the fit before pricing:
- Pump maker, model and serial number, with a nameplate photo
- Liner bore you run now and the bore you want to quote
- Fluid-end type and its pressure rating
- Rated and normal operating stroke rate
- Required flow and the circulating pressure you expect
- Part numbers or drawings for liners, pistons, valves and seats
A matching bore and stroke make the volume calculation match. They do not prove that a liner, piston or valve from another source fits the fluid end. Check fit against the maker's part numbers or drawings, as described in the mud pump spare parts guide.
Related pages: triplex and quintuplex drilling mud pumps, mud pump spare parts, pump strokes to volume calculator.
Authoritative references
- NOV 12-P-160 triplex mud pump technical marketing sheet: liner performance tablechecked 2026-11-01
- NOV mud pumps product page: 12-P-160 specificationschecked 2026-11-01