Parts & Compatibility
King Cobra VENOM Shaker Screens: Part Numbers and API Designations
Three King Cobra VENOM screen panels can all be labelled API 100 and still have different part numbers, measured cut points and conductance. On the NOV table, 6VNM140XF is sold under the catalogue label XF 140, but its API number is 100. If an old purchase order just says "140 screen," the label is not enough to tell which part was bought.
Six part numbers for two common API requests
The three VENOM series and six examples below come from page 2 of the NOV BRANDT VENOM screen data sheet. D100 is the measured cut point reported in micrometres. Conductance is reported in kD/mm, and the last column is non-blanked open area per panel in square metres.
| Part number | NOV label | API | D100 (µm) | kD/mm | Area (m²) |
|---|---|---|---|---|---|
6VNM140XF | XF 140 | 100 | 153 | 1.97 | 0.48 |
6VNM215RHD | RHD 215 | 100 | 142 | 2.18 | 0.48 |
M4A0041144 | PXL 100 | 100 | 159 | 1.87 | 0.49 |
6VNM210XF | XF 210 | 140 | 102 | 1.41 | 0.48 |
6VNM285RHD | RHD 285 | 140 | 98.3 | 1.58 | 0.48 |
M4A0041147 | PXL 140 | 140 | 112 | 1.57 | 0.49 |
These are selected catalogue rows, not an exhaustive list, an offer of genuine parts, or a current inventory statement. The NOV sheet groups these rows under COBRA-series and LCM-3D screens; a machine name from an invoice does not establish the basket and hardware currently on the rig.
What equal API numbers do not tell you
The API 100 examples in the table differ by 17 µm between the smallest and largest published D100 values. An order that specifies API 100 but no part number therefore leaves room for materially different quoted panels. Even within the same API designation, quoted screens are not interchangeable by designation alone.
Conductance and open area are useful comparison fields, not a published flow rate for the installed shaker. Evaluate them alongside the identified construction and the actual drilling fluid. Do not use the whole-shaker area to fill the panel area column, and do not convert trade names or wire mesh counts into API numbers. The screen label and replacement audit explains how to record missing evidence in a quotation.
Verify the installed basket before accepting a panel
The KING COBRA VENOM machine page describes pin-and-hole screen retention. For an existing machine, ask for the basket identification and a clear photo of the locating points and perimeter seal. Confirm the installed deck rather than relying on a sticker on the skid, particularly when a previous owner has changed the screen bed or retainer. The shaker screen size and mounting table distinguishes this system from wedge-held and draw-bolt references.
Review an old panel label in this order: transcribe the full part number; copy the printed API designation as a separate field; then compare the panel dimensions, locating features and seal with the requested assembly. If the nameplate or screen markings are unreadable, request a signed dimensional drawing before approving an alternate frame.
RFQ checklist for an exact replacement or a documented alternative
- Shaker model, serial number if available, and deck or basket revision.
- Old panel part number and label photo; required API designation and number of panels.
- Dimensions, pin locations, seal profile, and the material or duty requirements that affect the choice.
- Exact replacement or documented alternative, with every deviation identified in the quotation.
Use the screen RFQ to submit that information. Ask a bidder proposing a substitute to identify the offered part and attach its own dimensional and classification evidence, rather than copying the NOV table onto a different product.
Authoritative references
- NOV BRANDT VENOM screen sheet, Rev. 12: RHD, XF and PXL tableschecked 2026-11-21
- NOV King Cobra VENOM shaker: basket and screen retentionchecked 2026-11-21