AI category referenceAI-generated equipment category reference for Shale Shaker Screens; not an exact model photograph or specification evidence.

AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.

Solids Control & Mud Systems

Shale Shaker Screens

Replaceable shale shaker screen assemblies with named GN G75F part references, distinct API classification, conductance and non-blank-area evidence.

Documented model references
G75FGRA100C · G75FGRA140C
Parameters, conditions and sources
Technical files and replacement photos accepted
Final specifications subject to manufacturer confirmation

Source-bound technical references

Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.

G75FGRA100CD100 cut point
164 µm

G75F composite screen, exact part G75FGRA100C, API 100 catalogue row. Manufacturer reference in the filename-2018 brochure; not current stock, independent certification, field throughput or cross-brand fit approval.

PDF p.8, section 5.1, G75FGRA100C row, D100 cut point (um) column; visually inspected.

Revision 2018 in download filename; no separate revision identifier established · Checked 2026-10-23

G75FGRA100CScreen conductance
2.66 kD/mm

G75F composite screen, exact part G75FGRA100C, API 100 catalogue row. Manufacturer reference in the filename-2018 brochure; not current stock, independent certification, field throughput or cross-brand fit approval.

PDF p.8, section 5.1, G75FGRA100C row, Conductance (kD/mm) column; visually inspected.

Revision 2018 in download filename; no separate revision identifier established · Checked 2026-10-23

G75FGRA100CScreen non-blank area
5.2 ft²

G75F composite screen, exact part G75FGRA100C, API 100 catalogue row. Manufacturer reference in the filename-2018 brochure; not current stock, independent certification, field throughput or cross-brand fit approval. Standalone screen panel value, not whole-shaker deck area.

PDF p.8, section 5.1, G75FGRA100C row, Non-blank area (Sq.Ft) column; visually inspected.

Revision 2018 in download filename; no separate revision identifier established · Checked 2026-10-23

G75FGRA140CD100 cut point
101 µm

G75F composite screen, exact part G75FGRA140C, API 140 catalogue row. Manufacturer reference in the filename-2018 brochure; not current stock, independent certification, field throughput or cross-brand fit approval.

PDF p.8, section 5.1, G75FGRA140C row, D100 cut point (um) column; visually inspected.

Revision 2018 in download filename; no separate revision identifier established · Checked 2026-10-23

G75FGRA140CScreen conductance
1.89 kD/mm

G75F composite screen, exact part G75FGRA140C, API 140 catalogue row. Manufacturer reference in the filename-2018 brochure; not current stock, independent certification, field throughput or cross-brand fit approval.

PDF p.8, section 5.1, G75FGRA140C row, Conductance (kD/mm) column; visually inspected.

Revision 2018 in download filename; no separate revision identifier established · Checked 2026-10-23

G75FGRA140CScreen non-blank area
5.2 ft²

G75F composite screen, exact part G75FGRA140C, API 140 catalogue row. Manufacturer reference in the filename-2018 brochure; not current stock, independent certification, field throughput or cross-brand fit approval. Standalone screen panel value, not whole-shaker deck area.

PDF p.8, section 5.1, G75FGRA140C row, Non-blank area (Sq.Ft) column; visually inspected.

Revision 2018 in download filename; no separate revision identifier established · Checked 2026-10-23

Technical selection notes

Shale shaker screen sizes by model

Start with the shaker nameplate, not the mesh label. Panel size describes the outside frame; the API RP 13C number classifies the separation of an identified screen assembly. D100 is the measured cut point reported for that panel. The rows below are manufacturer reference examples, not an interchangeability chart or a stock list.

Shaker modelPanel sizeMounting referencePanel, API number and D100Manufacturer source
GNZS752F-MDZF750 × 900 mmGN family wedge-block retention; verify the installed deck revisionG75FGRA100C: API 100, 164 µmGN brochure dimensions, p. 10 and panel, p. 8; GN retention description
GNZS703F-SDZF / GNZS703F-SHBF700 × 1250 × 29 mmGN family wedge-block retention; verify the installed deck revisionG70FGRA140CG: API 140, 101 µmGN brochure dimensions, p. 10 and panel, p. 8; GN retention description
NOV BRANDT King Cobra VENOM1251 × 635 × 25 mmPin-and-hole screen securing; perimeter panel seal6VNM140XF: API 100, 153 µmNOV VENOM sheet: dimensions, securing system and XF series table
Derrick FLC 2000 (NOV replacement panel)1048 × 699 × 19 mmDerrick Rapid-Change draw-bolt tensioning; verify installed hardware64127HXTD140: API 100, 151 µmNOV replacement sheet, pp. 1–2; Derrick brochure, p. 21

Dimensions follow the cited sheets in their published order; no thickness is given for the GN 752F example in that table. The FLC 2000 row gives the dimensions of NOV's named replacement panel, not the dimensions of every Derrick panel. NOV calls 6VNM140XF XF 140, but the same row lists API 100. The suffix, API number and physical fit are not interchangeable.

For a replacement screen, record the old part number and measure the outer frame edge to edge, including thickness where accessible. Note the deck position, edge shape, locating holes or hooks, and seal profile. Use the API label and replacement audit guide to compare offers, or send those details in a screen RFQ.

For NOV BRANDT panels, check the King Cobra VENOM part-number and API table before comparing an XF, RHD or PXL offer.

Published manufacturer data is a selection reference, not a quotation or evidence of supply availability.

Product overview

Shale shaker screen assemblies, not just mesh labels

A replacement shaker screen is a framed screening assembly. The purchasing decision has to join separation designation, hydraulic characteristics and physical fit without treating any one of them as proof of the others. This page covers replaceable panels, not complete shakers, motors or a guaranteed drilling-fluid treatment rate.

GN Solids Control provides identifiable panel references in its screen brochure. The download filename identifies a historical 2018 brochure; it is not evidence of current inventory. Its G75F table names actual part numbers, allowing a buyer to discuss a specific panel construction rather than an unspecified family.

Named panel references

The following values come together from page 8, section 5.1, of that single retained brochure. They must stay attached to their respective part-number rows.

GN part numberCatalogue designationD100 cut pointConductanceNon-blank area
G75FGRA100CAPI 100164 µm2.66 kD/mm5.2 ft²
G75FGRA140CAPI 140101 µm1.89 kD/mm5.2 ft²

These are standalone G75F composite-screen references. The brochure associates this section with GNZS752F/GNZJ752F equipment; that association does not establish fit for a later shaker revision or another brand. Non-blank panel area is not the total screening area of a complete machine.

Match the panel before comparing price

Identify the installed shaker and deck revision, then record the old panel marking, frame dimensions, edge profile, fastening method and sealing arrangement. A clear label photograph and an existing spare can help identify the intended replacement. They do not authorize substituting a different frame that merely looks similar.

Keep the requested separation designation distinct from a surface-wire mesh description. Page 5 of the GN brochure explains why the cut point of a multilayer assembly cannot simply be read from its surface layer. An API designation is not a universal conversion from a seller's mesh count, nor evidence that this website or an offered shipment holds an API licence.

The useful comparison is therefore a matched set: part identity, panel classification, conductance, usable area and installation interface. A lower unit price is not a saving if the quotation leaves its panel construction unidentified. Equally, a finer designation should not be accepted as an automatic upgrade without the drilling-fluid team's duty assessment.

Separate a reference from an offered supply

Ask the bidder to state the manufacturer, exact proposed part number, frame construction, designation and any deviation from the reference. Where an alternative is offered, put the claimed fit and the supporting comparison in writing. Current availability, authorized distribution and delivery commitments remain quotation questions; the historical catalogue establishes none of them.

Material suitability, packing protection and storage requirements should be agreed against the intended fluid and logistics route. Order-specific drawings or test reports can then support the selected offer. Their absence does not prevent reading this informational reference, but unsupported equivalence must not become an unconditional purchase description.

Prepare the screen RFQ

For a structured bid review, use the screen designation and replacement audit guide. Include quantity, installed-machine identity, existing panel identification, requested designation, fluid context, destination and required delivery date in your RFQ. State whether an exact replacement or a documented alternative is acceptable.

If the requirement is actually for the complete screening machine, use the linear-motion shale shaker page. Panel procurement and whole-machine capacity selection require different evidence.

Technical reference trail

These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.

Frequently Asked Questions

Does API 100 mean a screen has 100-mesh surface wire?

No. The cited GN brochure distinguishes a multilayer assembly's cut-point classification from a single-layer mesh description. Request the identified panel and its declared classification rather than translating a mesh label.

Does the G75F table prove fit for my shaker?

No. It identifies historical GN panel references. Confirm installed deck revision, frame, seal and fixing interfaces; an unchanged designation or similar photograph is not a fit approval.

Is 5.2 ft² the screening area of the whole shaker?

No. It is the non-blank area listed for each named G75F screen panel, not the complete machine's deck area or a throughput guarantee.

Submit RFQ for Shale Shaker Screens

Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.

PDF, DOCX, XLSX, JPG, PNG or TXT. Up to 5 files, 10 MB each and 25 MB total.

Technical and RFQ References

Check common units, standards and purchasing terminology, then build a structured request for this equipment.