AI category referenceAI-generated equipment category reference for Drilling Fluid Decanter Centrifuges; not an exact model photograph or specification evidence.

AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.

Solids Control & Mud Systems

Drilling Fluid Decanter Centrifuges

Drilling-fluid decanter centrifuge reference with a single-edition GNLW363D-VFD geometry and main-drive basis, separated from feed-dependent process performance.

Documented model references
GNLW363D-VFD
Parameters, conditions and sources
Technical files and replacement photos accepted
Final specifications subject to manufacturer confirmation

Source-bound technical references

Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.

GNLW363D-VFDBowl diameter
360 mm

Exact GNLW363D-VFD column in the single retained GN equipment PDF, p.18. Reference VFD configuration only. Do not combine with GNLW363D, FHD, GP or another edition. No mud capacity, separation efficiency, certification or operating setpoint is established.

PDF p.18, section 2.5, GNLW363D-VFD column, Bowl Diameter row; visually inspected. Metric value used directly, not converted from nominal inches.

Revision Undated PDF; the retained byte hash identifies this edition · Checked 2026-10-23

GNLW363D-VFDBowl length
1271 mm

Exact GNLW363D-VFD column in the single retained GN equipment PDF, p.18. Reference VFD configuration only. Do not combine with GNLW363D, FHD, GP or another edition. No mud capacity, separation efficiency, certification or operating setpoint is established.

PDF p.18, section 2.5, GNLW363D-VFD column, Bowl Length row; visually inspected. Retain 1271, not a rounded 1270 from other documents.

Revision Undated PDF; the retained byte hash identifies this edition · Checked 2026-10-23

GNLW363D-VFDMain drive motor power
37 kW

Exact GNLW363D-VFD column in the single retained GN equipment PDF, p.18. Reference VFD configuration only. Do not combine with GNLW363D, FHD, GP or another edition. No mud capacity, separation efficiency, certification or operating setpoint is established. Main drive only; excludes back drive, feed pump and auxiliaries. Not shaft torque or complete-package input demand.

PDF p.18, section 2.5, GNLW363D-VFD column, Main Motor row; visually inspected.

Revision Undated PDF; the retained byte hash identifies this edition · Checked 2026-10-23

Product overview

Decanter centrifuges for a defined separation objective

A drilling-fluid decanter enquiry should start with what the buyer wants to retain, recover or reject. The same equipment family may be discussed for different fluid-management objectives, but that does not make its published capacity a universal treatment guarantee. Feed composition, the desired product streams and the proposed operating envelope belong in the process discussion.

This page provides a named GN Solids Control reference rather than an anonymous dimensional range. It covers a decanter centrifuge configuration, not an assurance that a complete feed, discharge, electrical and controls package is included in every offer.

Lock the reference to a single edition

The following entries are taken directly from the GNLW363D-VFD column on page 18, section 2.5, of the retained GN equipment catalogue. This PDF is undated; the saved snapshot and its hash identify the reviewed edition. These are independent geometry and drive parameters, not values decoded from the model name.

Exact GN configurationParameterCatalogue reference
GNLW363D-VFDBowl diameter360 mm
GNLW363D-VFDBowl length1271 mm
GNLW363D-VFDMain drive motor37 kW

The main-drive entry does not include the back drive, feed pump or ancillary loads. Bowl dimensions do not establish throughput, separation efficiency or a cut-point guarantee. The metric entries are retained as published rather than recalculated from nominal inch descriptions.

The general decanting-centrifuge page corroborates these particular geometry and main-motor entries, but other operating entries differ from the retained PDF. Do not combine the tables or transfer fixed-speed, hydraulic-drive or other suffix values to this VFD configuration. No differential-speed or flow value is adopted here.

Define the process before requesting capacity

Describe the feed source, fluid base, density and viscosity context, solids content, particle characteristics and expected variability. Then state the intended disposition of the separated liquid and solids. A clarification such as recovering useful liquid versus rejecting unwanted fine solids can change the basis on which proposals should be evaluated.

Ask the bidder to explain what evidence supports the proposed duty for that feed. The retained PDF explicitly qualifies its maximum capacity as a water reference and says treatment depends on material conditions and the required result. A water-based maximum must not be converted into a drilling-mud guarantee or combined with an attractive separation claim from another table.

Compare the complete package

A purchasing comparison should distinguish bowl geometry, main drive, back drive, feed equipment and controls. Confirm whether the offer includes the skid, guards, discharge interfaces and services relevant to the intended installation. These items affect procurement scope even when competing quotations cite the same centrifuge model.

Specify available utilities and the site's applicable electrical and area-classification requirements without assuming that a generic catalogue statement certifies the ordered assembly. Actual conformity documents, material options and manufacturer-approved operating limits remain configuration-specific. This reference neither grants a certification nor establishes authorized supply.

Turn the reference into an RFQ

Use the centrifuge duty and acceptance guide to structure feed information, proposed evidence and bid deviations. It separates process acceptance from mechanical catalogue data and keeps unresolved operating-table differences visible.

For a quotation, send the feed description, recovery objective, anticipated variation, package boundaries, utilities, destination and required documentation through the RFQ form. State which information is available now and which can follow during technical clarification. Order-controlled drawings and certificates can support the selected configuration without being prerequisites for understanding this informational family page.

Technical reference trail

These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.

Frequently Asked Questions

Why are no differential-speed or flow values adopted here?

The retained PDF and general GN webpage contain differing operating entries. This page locks its facts to the PDF's GNLW363D-VFD column and uses geometry and main-drive values only, not a cross-edition operating envelope.

Does the 37 kW entry describe the complete package's power?

No. It is the main drive motor entry for the cited GNLW363D-VFD configuration. The back drive, feed pump and auxiliaries are separate loads.

Can a catalogue water maximum be specified as guaranteed mud throughput?

No. The PDF expressly qualifies the maximum reference as water-based and makes treatment dependent on material conditions and the required result. Ask for a duty-specific assessment of the actual feed.

Submit RFQ for Drilling Fluid Decanter Centrifuges

Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.

PDF, DOCX, XLSX, JPG, PNG or TXT. Up to 5 files, 10 MB each and 25 MB total.

Technical and RFQ References

Check common units, standards and purchasing terminology, then build a structured request for this equipment.