AI category referenceAI-generated equipment category reference for High-Pressure Plug Valves; not an exact model photograph or specification evidence.

AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.

Cementing & Fracturing Equipment

High-Pressure Plug Valves

Compare identified Weco plug-valve catalogue configurations by service, cold working pressure, size and operator; request assembly-specific temperature, end-connection and test documents.

Documented model references
Weco ULT 150 P537789 · Weco ULT 100 (Manual) P501010
Parameters, conditions and sources
Named rows: 15,000 psi standard / 10,000 psi sour CWP; not a universal rangeP537789: 2 in; P501010: 3 in nominalManufacturer-specific catalogue reference; order-specific standards and acceptance documents require agreement
Technical files and replacement photos accepted
Final specifications subject to manufacturer confirmation

Source-bound technical references

Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.

Weco ULT 150 P537789Nominal size
2 in

Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.

PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; Nominal size, in. column

Checked 2026-10-23

Weco ULT 150 P537789Cold working pressure
15,000 psi

Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.

PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; CWP psi column

Checked 2026-10-23

Weco ULT 150 P537789Listed catalogue weight
84 lb

Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. Listed catalogue weight is not a lifting instruction.

PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; lb weight column

Checked 2026-10-23

Weco ULT 100 (Manual) P501010Nominal size
3 in

Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.

PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; Nominal size, in. column

Checked 2026-10-23

Weco ULT 100 (Manual) P501010Cold working pressure
10,000 psi

Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.

PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; CWP psi column

Checked 2026-10-23

Weco ULT 100 (Manual) P501010Listed catalogue weight
231 lb

Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. Listed catalogue weight is not a lifting instruction.

PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; lb weight column

Checked 2026-10-23

Technical selection notes

Catalogue values are attributed reference configurations, not a quotation, current stock, manufacturer authorization, independent certification or approval of an installed system. Every fact retains its exact maker, model, source and conditions. Selected normal P/N rows show no LT P/N; a general low-temperature introduction is not assigned to them. CWP and test pressure remain distinct.

Published manufacturer data is a selection reference, not a quotation or evidence of supply availability.

Product overview

Isolation valves with an identifiable catalogue configuration

High-pressure plug valves provide an isolation point in treating lines used for cementing, stimulation and related well-service operations. Selecting one requires more than a pressure class: the connection, service designation, operator and replacement-parts identity must describe the same assembly. This page uses named Weco catalogue examples to make that comparison concrete, without implying available stock, an authorized sales relationship or suitability for an unspecified well.

The TechnipFMC Flowline catalogue, printed page 8, identifies Weco ULT 150 P/N P537789 as a nominal 2-inch, standard-service valve with Weco 1502 ends, 15,000 psi cold working pressure and a listed weight of 84 lb. The same table identifies Weco ULT 100 P/N P501010 as a nominal 3-inch manual valve for sour service, also with 1502 ends, but with 10,000 psi cold working pressure and 231 lb listed weight. These are separate actual catalogue rows, not endpoints of a universal product range.

Read pressure and service together

The sour-service row is not a license to expose the standard-service valve to sour fluids. It also demonstrates why an end-connection figure cannot establish the valve's working pressure. Catalogue cold working pressure is not a test pressure, burst pressure or pressure-temperature curve. Neither example supplies a universally applicable hot-service rating on this page.

The low-temperature column is separate from the normal part-number column. The selected rows do not carry an LT part number; the catalogue's general low-temperature introduction must not be attached to them. Ask the manufacturer to issue the temperature, seal and material basis for the offered assembly, including fluid chemistry, inhibitors, solids and any sour-service requirements.

Choose the operator and installation envelope

Manual, handwheel and hydraulic variants appear elsewhere in the catalogue. An actuator change is an assembly change, not an accessory assumed to fit every body. State the required operation, available utilities, control interfaces and access for maintenance. Catalogue weight helps compare handling needs but is not a lifting instruction or a substitute for an installation drawing.

For replacement work, identify the installed maker, complete assembly number and serial marking before requesting internals. A familiar ULT name does not establish that a plug, seal segment, stem or kit from another size or manufacturer will fit. Keep the replacement request separate from a complete-valve alternative, and ask for the maker's applicable parts and maintenance documentation.

Put the unresolved engineering questions in the enquiry

Describe the intended isolation duty, operating and transient pressures, temperature envelope, media, flow direction and abrasive content. Include every mating connection, installation clearance, required operator and intended document package. Request a configuration-specific drawing, material and seal schedule, inspection scope and identifiable pressure-test record; agree the test basis rather than deriving it from the working-pressure number.

Use the plug-valve bid review guide to separate selection gaps from commercial exclusions. Submit the completed configuration record through the RFQ Builder, identifying whether the named catalogue item or an explicitly reviewed alternative is requested. The retained image is a category reference, not evidence of the valve's internal design, dimensions or certification.

Technical reference trail

These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.

Frequently Asked Questions

Does a 1502 end establish a plug valve working pressure?

No. The exact Weco rows differ: P537789 is standard service at 15,000 psi CWP, while manual sour-service P501010 is 10,000 psi CWP. The end designation is not a complete valve rating or cross-brand compatibility approval.

Can the catalogue low-temperature introduction be applied to P537789 or P501010?

No LT part number is shown for either selected row. Request a manufacturer-issued temperature, seal and material basis for the exact offered assembly; do not attach the general low-temperature option to these part numbers.

Is catalogue CWP the pressure for the requested acceptance test?

No. Agree a separate manufacturer-approved test procedure and traceable record for the selected configuration. The examples provide no test pressure or complete hot-service derating curve.

Submit RFQ for High-Pressure Plug Valves

Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.

PDF, DOCX, XLSX, JPG, PNG or TXT. Up to 5 files, 10 MB each and 25 MB total.

Technical and RFQ References

Check common units, standards and purchasing terminology, then build a structured request for this equipment.