AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.
Cementing & Fracturing Equipment
High-Pressure Plug Valves
Compare identified Weco plug-valve catalogue configurations by service, cold working pressure, size and operator; request assembly-specific temperature, end-connection and test documents.
- Documented model references
- Weco ULT 150 P537789 · Weco ULT 100 (Manual) P501010
- Parameters, conditions and sources
Source-bound technical references
Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.
- Weco ULT 150 P537789Nominal size
- 2 in
Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.
PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; Nominal size, in. columnChecked 2026-10-23
- Weco ULT 150 P537789Cold working pressure
- 15,000 psi
Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.
PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; CWP psi columnChecked 2026-10-23
- Weco ULT 150 P537789Listed catalogue weight
- 84 lb
Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. Listed catalogue weight is not a lifting instruction.
PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; lb weight columnChecked 2026-10-23
- Weco ULT 100 (Manual) P501010Nominal size
- 3 in
Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.
PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; Nominal size, in. columnChecked 2026-10-23
- Weco ULT 100 (Manual) P501010Cold working pressure
- 10,000 psi
Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve.
PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; CWP psi columnChecked 2026-10-23
- Weco ULT 100 (Manual) P501010Listed catalogue weight
- 231 lb
Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. Listed catalogue weight is not a lifting instruction.
PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; lb weight columnChecked 2026-10-23
| Model | Parameter | Reference value | Conditions and source |
|---|---|---|---|
| Weco ULT 150 P537789 | Nominal size | 2 in | Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; Nominal size, in. columnChecked 2026-10-23 |
| Weco ULT 150 P537789 | Cold working pressure | 15,000 psi | Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; CWP psi columnChecked 2026-10-23 |
| Weco ULT 150 P537789 | Listed catalogue weight | 84 lb | Exact P/N P537789, Weco ULT 150, standard service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. Listed catalogue weight is not a lifting instruction. PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P537789 row; rendered fmc-p10.png; lb weight columnChecked 2026-10-23 |
| Weco ULT 100 (Manual) P501010 | Nominal size | 3 in | Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; Nominal size, in. columnChecked 2026-10-23 |
| Weco ULT 100 (Manual) P501010 | Cold working pressure | 10,000 psi | Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; CWP psi columnChecked 2026-10-23 |
| Weco ULT 100 (Manual) P501010 | Listed catalogue weight | 231 lb | Exact P/N P501010, Weco ULT 100 manual, sour service, Weco 1502 ends; no LT P/N shown. CWP only, not test pressure or a hot-service curve. Listed catalogue weight is not a lifting instruction. PDF page 10 / printed page 8, Weco plug valve specifications, exact P/N P501010 row; rendered fmc-p10.png; lb weight columnChecked 2026-10-23 |
Technical selection notes
Catalogue values are attributed reference configurations, not a quotation, current stock, manufacturer authorization, independent certification or approval of an installed system. Every fact retains its exact maker, model, source and conditions. Selected normal P/N rows show no LT P/N; a general low-temperature introduction is not assigned to them. CWP and test pressure remain distinct.
Published manufacturer data is a selection reference, not a quotation or evidence of supply availability.
Product overview
Isolation valves with an identifiable catalogue configuration
High-pressure plug valves provide an isolation point in treating lines used for cementing, stimulation and related well-service operations. Selecting one requires more than a pressure class: the connection, service designation, operator and replacement-parts identity must describe the same assembly. This page uses named Weco catalogue examples to make that comparison concrete, without implying available stock, an authorized sales relationship or suitability for an unspecified well.
The TechnipFMC Flowline catalogue, printed page 8, identifies Weco ULT 150 P/N P537789 as a nominal 2-inch, standard-service valve with Weco 1502 ends, 15,000 psi cold working pressure and a listed weight of 84 lb. The same table identifies Weco ULT 100 P/N P501010 as a nominal 3-inch manual valve for sour service, also with 1502 ends, but with 10,000 psi cold working pressure and 231 lb listed weight. These are separate actual catalogue rows, not endpoints of a universal product range.
Read pressure and service together
The sour-service row is not a license to expose the standard-service valve to sour fluids. It also demonstrates why an end-connection figure cannot establish the valve's working pressure. Catalogue cold working pressure is not a test pressure, burst pressure or pressure-temperature curve. Neither example supplies a universally applicable hot-service rating on this page.
The low-temperature column is separate from the normal part-number column. The selected rows do not carry an LT part number; the catalogue's general low-temperature introduction must not be attached to them. Ask the manufacturer to issue the temperature, seal and material basis for the offered assembly, including fluid chemistry, inhibitors, solids and any sour-service requirements.
Choose the operator and installation envelope
Manual, handwheel and hydraulic variants appear elsewhere in the catalogue. An actuator change is an assembly change, not an accessory assumed to fit every body. State the required operation, available utilities, control interfaces and access for maintenance. Catalogue weight helps compare handling needs but is not a lifting instruction or a substitute for an installation drawing.
For replacement work, identify the installed maker, complete assembly number and serial marking before requesting internals. A familiar ULT name does not establish that a plug, seal segment, stem or kit from another size or manufacturer will fit. Keep the replacement request separate from a complete-valve alternative, and ask for the maker's applicable parts and maintenance documentation.
Put the unresolved engineering questions in the enquiry
Describe the intended isolation duty, operating and transient pressures, temperature envelope, media, flow direction and abrasive content. Include every mating connection, installation clearance, required operator and intended document package. Request a configuration-specific drawing, material and seal schedule, inspection scope and identifiable pressure-test record; agree the test basis rather than deriving it from the working-pressure number.
Use the plug-valve bid review guide to separate selection gaps from commercial exclusions. Submit the completed configuration record through the RFQ Builder, identifying whether the named catalogue item or an explicitly reviewed alternative is requested. The retained image is a category reference, not evidence of the valve's internal design, dimensions or certification.
Technical reference trail
These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.
Frequently Asked Questions
Does a 1502 end establish a plug valve working pressure?
No. The exact Weco rows differ: P537789 is standard service at 15,000 psi CWP, while manual sour-service P501010 is 10,000 psi CWP. The end designation is not a complete valve rating or cross-brand compatibility approval.
Can the catalogue low-temperature introduction be applied to P537789 or P501010?
No LT part number is shown for either selected row. Request a manufacturer-issued temperature, seal and material basis for the exact offered assembly; do not attach the general low-temperature option to these part numbers.
Is catalogue CWP the pressure for the requested acceptance test?
No. Agree a separate manufacturer-approved test procedure and traceable record for the selected configuration. The examples provide no test pressure or complete hot-service derating curve.
Submit RFQ for High-Pressure Plug Valves
Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.
Technical and RFQ References
Check common units, standards and purchasing terminology, then build a structured request for this equipment.
Related Products

Oilfield Hammer Unions
Identify hammer unions by maker, complete part number, size, end preparation and non-shock cold working pressure. Dixon references do not establish Weco compatibility or sour/hot-service approval.

High-Pressure Flowline and Treating Iron
High-Pressure Flowline and Treating Iron for cementing, well stimulation, fracturing and high-pressure fluid routing, with quotation fields for working and test pressure, nominal size, union figure or flange, temperature, material, sour-service requirement, erosion allowance, flow direction and required NDT/test records.
Related Technical Articles
Plug Valve Bid Review: Service, Operator and Pressure Boundaries
Follow one plug-valve configuration across the service, pressure, actuator and replacement-parts documents before comparing bids.
Oilfield Equipment Supplier RFQ Guide
How buyers can compare oilfield equipment suppliers and prepare RFQs for wellhead equipment, drilling tools, pressure-control parts, and oilfield spares.