AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.
Cementing & Fracturing Equipment
Oilfield Hammer Unions
Identify hammer unions by maker, complete part number, size, end preparation and non-shock cold working pressure. Dixon references do not establish Weco compatibility or sour/hot-service approval.
- Documented model references
- Dixon Series 1502 HU1502200 · Dixon Series 1502 HU1502300BW
- Parameters, conditions and sources
Source-bound technical references
Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.
- Dixon Series 1502 HU1502200Nominal connection size
- 2 in
Exact Dixon P/N HU1502200, threaded, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim.
DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502200; rendered dixon-p1.png; Medida columnChecked 2026-10-23
- Dixon Series 1502 HU1502200Non-shock cold working pressure (NSCWP)
- 15,000 psi
Exact Dixon P/N HU1502200, threaded, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim.
DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502200; rendered dixon-p1.png; NSCWP (PSI) columnChecked 2026-10-23
- Dixon Series 1502 HU1502300BWNominal connection size
- 3 in
Exact Dixon P/N HU1502300BW, butt-weld; weld-end footnote XXS schedule, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim.
DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502300BW; rendered dixon-p1.png; Medida columnChecked 2026-10-23
- Dixon Series 1502 HU1502300BWNon-shock cold working pressure (NSCWP)
- 15,000 psi
Exact Dixon P/N HU1502300BW, butt-weld; weld-end footnote XXS schedule, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim.
DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502300BW; rendered dixon-p1.png; NSCWP (PSI) columnChecked 2026-10-23
| Model | Parameter | Reference value | Conditions and source |
|---|---|---|---|
| Dixon Series 1502 HU1502200 | Nominal connection size | 2 in | Exact Dixon P/N HU1502200, threaded, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim. DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502200; rendered dixon-p1.png; Medida columnChecked 2026-10-23 |
| Dixon Series 1502 HU1502200 | Non-shock cold working pressure (NSCWP) | 15,000 psi | Exact Dixon P/N HU1502200, threaded, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim. DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502200; rendered dixon-p1.png; NSCWP (PSI) columnChecked 2026-10-23 |
| Dixon Series 1502 HU1502300BW | Nominal connection size | 3 in | Exact Dixon P/N HU1502300BW, butt-weld; weld-end footnote XXS schedule, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim. DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502300BW; rendered dixon-p1.png; Medida columnChecked 2026-10-23 |
| Dixon Series 1502 HU1502300BW | Non-shock cold working pressure (NSCWP) | 15,000 psi | Exact Dixon P/N HU1502300BW, butt-weld; weld-end footnote XXS schedule, forged steel, Series 1502; catalogue describes water, oil or mud. Non-shock cold working pressure only; not hot-service, sour-service or test-pressure approval. No cross-brand mating claim. DSC2023 PDF page 1 / printed page 997, Series 1502 row HU1502300BW; rendered dixon-p1.png; NSCWP (PSI) columnChecked 2026-10-23 |
Technical selection notes
Catalogue values are attributed reference configurations, not a quotation, current stock, manufacturer authorization, independent certification or approval of an installed system. Every fact retains its exact maker, model, source and conditions. Dixon NSCWP values are not borrowed from Weco. The saved Weco file has conflicting Figure 1502 pressure headings (printed pp48/54); neither is adopted as a confirmed part rating. The page-54 non-pressure-seal footnote is not generalized to every row.
Published manufacturer data is a selection reference, not a quotation or evidence of supply availability.
Product overview
Hammer unions selected as complete identified connections
An oilfield hammer union joins pressure-containing line components through a male sub, female sub and union nut. The purchasing problem is not simply finding a familiar figure number. The complete connection must have an identified manufacturer, size, end preparation, service and rating, with mating components accepted by that manufacturer. This reference page supports a technical enquiry; it does not certify an installed string or promise that different manufacturers' parts interchange.
The Dixon DSC2023 catalogue, printed page 997 lists Series 1502 P/N HU1502200 as a 2-inch threaded forged-steel union at 15,000 psi NSCWP. It separately lists P/N HU1502300BW as a 3-inch butt-weld forged-steel union at the same non-shock cold working pressure. The weld-end footnote specifies XXS schedule. Size, configuration and pressure are printed table fields, not values decoded from either part number.
Use the catalogue rating without extending it
Dixon describes this series for water, oil or mud. NSCWP means non-shock cold working pressure; it does not describe a pressure test or approve shock loading. The saved catalogue page does not give a configuration-specific hot-service derating curve, sour-service acceptance or test pressure. Those items remain enquiry requirements, not blank spaces to fill using another brand's catalogue.
The separately saved Weco catalogue has inconsistent Figure 1502 pressure headings between printed pages 48 and 54; page 54 also includes a non-pressure-seal footnote. This edition-specific discrepancy is not resolved here. Neither heading is used to assign a confirmed pressure to its listed union part numbers, and neither modifies the Dixon rows.
The threaded and butt-weld examples are not interchangeable installation options without review. For threaded connections, define the mating pipe and required thread details. For welded connections, provide pipe material, wall, weld-end preparation and the project's welding and inspection responsibilities. A catalogue's XXS note does not constitute a qualified welding procedure or confirmation that existing pipe matches the proposed end.
Identify both sides before requesting replacements
Record the manufacturer's markings on the nut and both subs, their figure, size, pressure and service designation, plus photographs that retain identifying marks. A connection that appears to engage is not proven compatible. Colour can help identify a manufacturer's series but cannot authenticate a component or establish that a mixed set is safe.
The TechnipFMC warnings, printed page 88 prohibit substituting non-TechnipFMC parts into its assemblies and mixing different pressure ratings. That is a manufacturer-specific restriction, not a claim that Dixon and Weco parts are equivalent. Ask the responsible maker to resolve every uncertain mating interface before accepting a substitution.
Quote the assembly and acceptance scope separately
State whether the enquiry covers a complete union, a weld-end assembly, or a maker-identified replacement component. List operating pressure, temperature, media, sour constituents if present, external loads, pipe interfaces and required traceability. Request the selected manufacturer's dimensional and material documents, assembly instructions and agreed inspection/test records. Do not call a catalogue standard reference an independently verified certificate.
The hammer-union identification guide provides a connection register and a procedure for resolving mixed or unmarked inventory. Send that register with the RFQ Builder. The retained illustration shows the equipment category only; it is not an exact Dixon model photograph, a dimensional inspection or evidence of current supply.
Technical reference trail
These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.
Frequently Asked Questions
Can Dixon and Weco parts be mixed when both say Figure or Series 1502?
No compatibility conclusion follows from that shared designation. TechnipFMC prohibits non-TechnipFMC components in its assemblies; identify the maker and full configuration of each sub and nut and obtain the responsible manufacturer's decision.
Is 15,000 psi NSCWP a test pressure or a hot-service rating?
Neither. The Dixon page identifies non-shock cold working pressure for the named water/oil/mud configurations. A test procedure, pressure-temperature basis and special-service acceptance must be requested separately.
Does the Weco page-54 pressure heading change the Dixon reference?
No. The saved Weco file has inconsistent Figure 1502 pressure headings and a non-pressure-seal footnote. That unresolved edition-specific text is not adopted as a confirmed Weco part rating and cannot be transferred to Dixon.
Submit RFQ for Oilfield Hammer Unions
Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.
Technical and RFQ References
Check common units, standards and purchasing terminology, then build a structured request for this equipment.
Related Products

High-Pressure Plug Valves
Compare identified Weco plug-valve catalogue configurations by service, cold working pressure, size and operator; request assembly-specific temperature, end-connection and test documents.

High-Pressure Flowline and Treating Iron
High-Pressure Flowline and Treating Iron for cementing, well stimulation, fracturing and high-pressure fluid routing, with quotation fields for working and test pressure, nominal size, union figure or flange, temperature, material, sour-service requirement, erosion allowance, flow direction and required NDT/test records.

Frac Heads and Goat Heads
Frac Heads and Goat Heads for cementing, well stimulation, fracturing and high-pressure fluid routing, with quotation fields for working and test pressure, nominal size, union figure or flange, temperature, material, sour-service requirement, erosion allowance, flow direction and required NDT/test records.
Related Technical Articles
Hammer Union Mismatch Review: Build a Connection Register
Identify both subs and the nut, separate catalogue configurations from figure labels, and resolve mixed-maker connections without trial assembly.
Oilfield Equipment Supplier RFQ Guide
How buyers can compare oilfield equipment suppliers and prepare RFQs for wellhead equipment, drilling tools, pressure-control parts, and oilfield spares.