OILFIELD RFQ
EquipmentCalculatorsGuides
Submit RFQ
Home/Products/Surface Production & Well Testing/Surface Test Manifolds and ESD Systems
High-pressure surface test manifold with actuated valves and shutdown controls

Surface Production & Well Testing

Surface Test Manifolds and ESD Systems

Surface Test Manifolds and ESD Systems for routing, isolation, pressure control and emergency shutdown between the wellhead, separator, metering and disposal equipment, with RFQ fields covering inlet and outlet pressure classes, line sizes, flow paths, adjustable and fixed chokes, valve type and actuation, sour and erosive service, temperature, piping class, relief and bleed-down, shutdown valves, sensors, logic, fail positions, interfaces and skid lifting limits.

Inlet and downstream pressure classesLine, choke and valve sizesAPI 6A or project piping class where applicable / ESD cause-and-effect specification
Request a quotationBuild RFQ checklist
Technical files and replacement photos accepted
Final specifications subject to manufacturer confirmation

On this page

  • Specifications
  • Overview
  • Sources
  • FAQ
  • Request a quotation

RFQ selection reference

Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.

ParameterReference valueNotes
Flow pathInlet and downstream pressure classesLine, choke and valve sizesAttach the approved process flow diagram
Materials and erosionDesign pressure and temperatureTrim, piping class and sour-service basisState sand rate and choke duty cycle
Shutdown systemActuated valves, sensors and logic solverFail positions and bleed-down sequenceProvide cause-and-effect and interface schedule

Product overview

Product scope

Surface Test Manifolds and ESD Systems are presented as a quotation-ready product family for routing, isolation, pressure control and emergency shutdown between the wellhead, separator, metering and disposal equipment. This page supports early technical comparison; it does not identify one guaranteed model, stocked unit or universal configuration. The final supplier and manufacturer must confirm the ordered design against the buyer's datasheet, project specification, applicable code editions and signed quotation.

Selection basis

The main selection inputs are inlet and outlet pressure classes, line sizes, flow paths, adjustable and fixed chokes, valve type and actuation, sour and erosive service, temperature, piping class, relief and bleed-down, shutdown valves, sensors, logic, fail positions, interfaces and skid lifting limits. These fields affect equipment fit, performance, safety, documentation, transport and total package price. For replacement equipment, include the installed maker, model, serial number, original part number, clear nameplate photographs and interface drawings. For a new package, attach process cases, site data, governing specifications and the latest approved standard editions.

Configuration reference

The table above is a structured RFQ reference rather than a manufacturer model list. It shows the information required to compare technically responsive quotations. Public standards and manufacturer examples identify common architecture and purchasing fields only; they do not imply dealership, authorization, stock ownership or identical performance across suppliers.

Documents and inspection

Define the document package before commercial evaluation. Depending on the equipment, request signed datasheets, process and instrumentation diagrams, general arrangement and interface drawings, design calculations, material certificates, pressure or performance test reports, NDT records, hazardous-area certificates, inspection and test plan, preservation procedure, packing list, lifting plan, marking photographs and certificate of conformity. Verify the exact code edition, certificate scope, manufacturing facility and offered model before purchase-order release.

RFQ checklist

  • Product family, service, quantity and required delivery date
  • Operating cases, pressure or load, temperature, flow and process media
  • Dimensions, connections, materials and approved standard edition
  • Site utilities, ambient conditions and hazardous-area classification
  • Required testing, third-party inspection, traceability and document language
  • Destination, Incoterm, packing, lifting and transport restrictions
  • Target unit price or budget range and acceptable technical alternatives

Upload the specification, drawing, equipment list, process data or replacement photographs with the inquiry. Open technical points and supplier deviations should be closed before price comparison and order release.

Technical reference trail

These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.

  • SLB surface well-testing equipment portfolioChecked 2026-08-26
  • American Petroleum Institute: active standards catalogChecked 2026-08-26

Frequently Asked Questions

What information is required to quote Surface Test Manifolds and ESD Systems?

Provide inlet and outlet pressure classes, line sizes, flow paths, adjustable and fixed chokes, valve type and actuation, sour and erosive service, temperature, piping class, relief and bleed-down, shutdown valves, sensors, logic, fail positions, interfaces and skid lifting limits, quantity, destination, delivery target and the required document package. Attach the project datasheet, process data or matching equipment drawing whenever available.

Are the displayed specifications guaranteed values?

No. They are RFQ reference fields. The final manufacturer datasheet, approved drawings, calculations, test procedure and purchase specification control the ordered equipment.

Can an equivalent configuration be quoted?

Yes, when the buyer permits alternatives. Every deviation in standard, rating, material, interface, certification, testing or delivery scope should be listed clearly for technical review.

Submit RFQ for Surface Test Manifolds and ESD Systems

Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.

PDF, DOCX, XLSX, JPG, PNG or TXT. Up to 5 files, 10 MB each and 25 MB total.

Technical and RFQ References

Check common units, standards and purchasing terminology, then build a structured request for this equipment.

Oilfield Unit ConverterAPI Standards NavigatorEquipment GlossaryBuild a Structured RFQ

Related Products

Instrumented horizontal well test separator with piping and controls

Two- and Three-Phase Well Test Separators

Two- and Three-Phase Well Test Separators for separation and individual measurement of gas, oil, water and limited solids during cleanup, flowback and production testing, with RFQ fields covering minimum, normal and maximum wellstream rates, phase fractions, pressure and temperature, fluid properties, gas-oil ratio, water cut, sand and foam, retention time, two- or three-phase duty, vessel orientation, pressure rating, sour service, metering, controls, relief system and skid transport limits.

Vertical sand separator and desander integrated with a surface testing skid

Wellhead Sand Separators and Desanders

Wellhead Sand Separators and Desanders for removal and controlled collection of produced sand and solids upstream of test or production equipment during flowback and cleanup, with RFQ fields covering gas and liquid rate, pressure, temperature, sand loading and particle distribution, erosion velocity, vessel or cyclonic design, dump frequency, solids collection volume, liner material, choke integration, relief, instrumentation, sour service and disposal method.

Vertical surge tank and atmospheric gauge tank for well testing liquids

Surge Tanks and Atmospheric Gauge Tanks

Surge Tanks and Atmospheric Gauge Tanks for liquid buffering, gas breakout, volume gauging and controlled transfer downstream of well-test separation equipment, with RFQ fields covering pressurized surge or atmospheric duty, operating pressure and temperature, liquid rate, surge volume, residence time, fluid properties, gas breakout, level measurement, vent and relief routing, transfer pumps, sampling, sour service, hazardous area and transport format.

Skid-mounted well test heat exchanger integrated with separator piping

Well Test Heaters and Heat Exchangers

Well Test Heaters and Heat Exchangers for wellstream heating or cooling to manage hydrate, wax, viscosity, separation and disposal conditions during surface testing, with RFQ fields covering wellstream composition and rates, inlet and outlet temperature, pressure, heat duty, utility medium, fouling and solids, pressure drop, metallurgy, exchanger type, burner or steam requirements, control philosophy, relief, hazardous area, sour service and skid limits.

Related Technical Articles

API Standard Edition and Document Checks Before an Oilfield Order

A pre-order checklist for confirming API standard editions, addenda, errata, supplier scope and required product records.

7 min read

API 6A Wellhead Equipment Buying Guide

Key information buyers should prepare before requesting quotes for API 6A wellhead equipment, christmas trees, valves, and related parts.

4 min read

Material Certificates and Inspection Documents for Oilfield RFQs

Understand which material, test, inspection and traceability documents to request before comparing oilfield equipment quotations.

7 min read

OILFIELD RFQ

Technical references, practical calculations and structured equipment requests for the oilfield industry.

Equipment

  • Wellhead & Pressure Control
  • Drilling & Downhole Tools
  • Mud Pump & Rig Spares
  • Sourcing & Export

Resources

  • Buyer Guides
  • Calculators & RFQ Builder
  • Equipment Reference
  • API Standards Navigator
  • FAQ
  • Procurement Glossary
  • Solutions
  • About Us
  • Contact

Contact

  • Submit RFQ online
  • China

© 2026 OILFIELD RFQ SOURCING. All rights reserved.

Privacy Policy|Terms of Service