OILFIELD RFQ
EquipmentCalculatorsGuides
Submit RFQ
Home/Products/Produced Water & Gas Treatment/On-site PSA Nitrogen Generation Packages
AI category referenceAI-generated on-site psa nitrogen generation packages category reference; not an exact-model photograph

AI-generated category reference. It is not a photograph of a specific manufacturer or exact product model.

Produced Water & Gas Treatment

On-site PSA Nitrogen Generation Packages

Compare PSA nitrogen packages by source-bound flow, purity, pressure and air-treatment conditions before defining the quotation scope.

Documented model references
DTD-200/0.8 · DTD-500/0.8
Parameters, conditions and sources
Request a quotationAdd to RFQ
Technical files and replacement photos accepted
Final specifications subject to manufacturer confirmation

On this page

  • Specifications
  • Technical notes
  • Overview
  • Sources
  • FAQ
  • Request a quotation

Source-bound technical references

Reference fields for quotation comparison. Final values must be confirmed in the signed manufacturer datasheet.

ModelParameterReference valueConditions and source
On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceProcessCarbon molecular sieve PSA air separation

Compressed air is treated before the alternating adsorption/regeneration beds; process explanation, not a performance warranty.

PSA nitrogen process flow / carbon molecular sieve

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceCustom package flow range10 to 10000 Nm3/h

Custom package family only. Not paired with every purity or pressure. Feed-air/design conditions absent from this range.

Custom packages / specification parameters

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceNitrogen purity range95 to 99.9995 % (N2 + Ar)

Technical page explicitly uses N2+Ar; FAQ explains residual-oxygen-based indication. No model-specific endpoint combination implied.

PSA product specifications / purity

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceCustom package nitrogen pressure5 to 10 bar

Product page does not specify gauge/absolute pressure; do not silently add barg. No flow-purity-pressure guarantee inferred.

Custom packages / specification parameters

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceCustom package installationambientMin: 2; ambientMax: 40; installation: Indoor; frost-free; load-bearing concrete floor; good ventilation degC for ambient

Only custom-package subsection; not a DT model or outdoor/marine temperature qualification.

Custom packages / environment and installation conditions

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceControl and package formcontrol: Local PLC; communication to main control room; form: Usually skid-mounted; container form can be designed in special cases

Customization statement, not an included interface/protocol or stocked configuration.

Custom packages / controls and package form

Checked 2026-10-23

DTD-200/0.8Listed nitrogen flow200 Nm3/h

Surface-installed DT series for coal-mining applications. Source prints 200N m3/h and Mpa; typography normalized only. Gauge/absolute pressure, feed-air conditions and argon treatment are not specified in the row. FAQ provides company general normal-volume basis, not a controlled model sheet.

Specification parameters / DTD-200/0.8 row

Checked 2026-10-23

DTD-200/0.8Listed minimum nitrogen purity>= 98 %

Surface-installed DT series for coal-mining applications. Source prints 200N m3/h and Mpa; typography normalized only. Gauge/absolute pressure, feed-air conditions and argon treatment are not specified in the row. FAQ provides company general normal-volume basis, not a controlled model sheet.

Specification parameters / DTD-200/0.8 row

Checked 2026-10-23

DTD-200/0.8Listed nitrogen pressure0.5 to 0.8 MPa

Surface-installed DT series for coal-mining applications. Source prints 200N m3/h and Mpa; typography normalized only. Gauge/absolute pressure, feed-air conditions and argon treatment are not specified in the row. FAQ provides company general normal-volume basis, not a controlled model sheet.

Specification parameters / DTD-200/0.8 row

Checked 2026-10-23

DTD-500/0.8Listed nitrogen flow500 Nm3/h

Same surface-installed DT series for coal-mining applications, not evidence of oilfield duty. Gauge/absolute pressure, feed-air conditions and argon treatment are not specified in the row.

Specification parameters / DTD-500/0.8 row

Checked 2026-10-23

DTD-500/0.8Listed minimum nitrogen purity>= 98 %

Same surface-installed DT series for coal-mining applications, not evidence of oilfield duty. Gauge/absolute pressure, feed-air conditions and argon treatment are not specified in the row.

Specification parameters / DTD-500/0.8 row

Checked 2026-10-23

DTD-500/0.8Listed nitrogen pressure0.5 to 0.8 MPa

Same surface-installed DT series for coal-mining applications, not evidence of oilfield duty. Gauge/absolute pressure, feed-air conditions and argon treatment are not specified in the row.

Specification parameters / DTD-500/0.8 row

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceGeneral flow reference statetemperature: 0; pressure: 0.101325 degC; MPa

FAQ question 17 says company generally uses this normal-volume basis. Must still state the reference state in the issued quotation; do not convert model flow values silently.

FAQ 17

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referencePretreatment sensitivityOil, water and particles require air treatment; inlet pressure/temperature affect capacity

General FAQ/process guidance. No ISO 8573 class, guaranteed dew point, feed rate or kWh/Nm3 assigned to a specific model.

FAQ 8, 14, 15

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referenceModular family scopeModular nitrogen generation for small and medium demands; oil/gas onshore and offshore applications are listed

Family/application statement only, not model-specific performance data. Marine certification, lead time and stock status are not established.

Modular nitrogen generators / applications and supporting equipment illustrations

Checked 2026-10-23

On-site PSA Nitrogen Generation Packages (family reference; no model code)Family catalogue referencePurging applicationNitrogen for purging, displacement and blanketing is discussed alongside both membrane and PSA systems

Application page combines technologies. High-pressure membrane figures must not migrate to PSA packages.

Pipeline purging application article

Checked 2026-10-23

Technical selection notes

Source-bound catalogue references are not an order-specific performance, certification or supply guarantee.

Published manufacturer data is a selection reference, not a quotation or evidence of supply availability.

Product overview

A nitrogen utility package, not a natural-gas treating unit

An on-site PSA nitrogen package addresses a utility-supply question: what nitrogen quality and delivery profile does the plant need, and what compressed-air system can support it? It should not be specified as a substitute for TEG dehydration or amine sweetening. The SMC-IGS technical description presents an air-separation process using carbon molecular sieve, with treated compressed air feeding beds that alternate between adsorption and regeneration. The family reference below is intended to help define that enquiry, rather than to imply that a single standard skid covers every duty.

Package boundary and configuration

The manufacturer's custom-package page describes local PLC control, communication with a central control room and a normally skid-mounted arrangement; a container arrangement is a design option. Its modular page identifies another packaging route for smaller and medium nitrogen demands. For an RFQ, ask the bidder to identify which equipment is inside the quoted boundary: air compression, drying and filtration, nitrogen generation, buffer vessels, analysis and any boosting equipment. Do not assume that a protocol, compressor or high-pressure booster is included merely because it appears in a family illustration.

Read capability ranges as ranges, not as one operating point

The custom-package listing gives a flow envelope of 10–10,000 Nm³/h and a nitrogen-pressure envelope of 5–10 bar; its pressure notation does not identify gauge or absolute basis. The technical page gives a purity range of 95–99.9995% on an N₂+Ar basis. Those are separate family statements, not a promise to achieve all maxima together. Its custom-package installation description also refers to indoor, frost-free, ventilated installation on a suitable concrete floor, with a 2–40°C ambient range. Those conditions must not be copied onto an outdoor, marine or mining configuration without a matching design basis.

A traceable model example

SMC's DT-series page for surface-installed coal-mine nitrogen generators lists DTD-200/0.8 at 200 Nm³/h, at least 98% purity and 0.5–0.8 MPa nitrogen pressure. This is a row from that surface-installed series, not a general oilfield qualification. The webpage leaves inlet conditions and pressure-reference convention unspecified. SMC's general FAQ identifies 0°C and 0.101325 MPa as its normal-volume reference, but the quotation should repeat the agreed reference state and purity definition explicitly. A model name is useful evidence of a listed configuration; it is not proof of a current issued design, certification or availability.

What to put into the enquiry

State continuous and peak demand separately, the minimum acceptable quality at the user connection, normal and minimum delivery pressure, operating hours and foreseeable expansion. Ask how analyser readings define nitrogen quality, including argon and residual oxygen. Supply the actual available air-pressure and temperature envelope, contamination information and utilities. The official FAQ highlights air-treatment maintenance and pressure/temperature sensitivity; it does not provide a universal consumption guarantee. Request an agreed guaranteed-point schedule, utility balance, controls description and acceptance procedure, rather than estimating performance from the highest number in each brochure column.

Drawings, application and commercial limits

SMC discusses purging, displacement and blanketing applications, but that page covers both membrane and PSA equipment. High-pressure membrane statements are not PSA ratings. Agree the final arrangement, vessel documentation and tie-in drawings as quotation and engineering deliverables. Catalogue references do not establish project certification, availability or manufacturer authorization. The selected package still needs a documented performance point and installation review before purchase.

Specify the nitrogen guarantee point, purity definition and feed-air boundary in PSA Nitrogen Selection: Flow, Purity and Normal-Volume Basis.

Technical reference trail

These public references support the equipment family and selection context. They do not imply dealership, authorization or a guaranteed order specification.

  • PSA technology and product specificationsChecked 2026-10-23
  • PSA nitrogen product familyChecked 2026-10-23
  • Surface-installed DT series for coal-mining applicationsChecked 2026-10-23
  • Gas separation FAQChecked 2026-10-23
  • Modular nitrogen generatorsChecked 2026-10-23
  • Pipeline purging applicationsChecked 2026-10-23

Frequently Asked Questions

Can I combine the highest published nitrogen flow, purity and pressure into one guaranteed duty?

No. The published ranges are separate family statements, not a simultaneous operating point. Request a guaranteed-point schedule that states the nitrogen quality definition, including argon, the normal-volume reference and the pressure basis, together with the available feed-air conditions.

What should the quotation include besides the PSA nitrogen generator?

Ask the bidder to identify whether air compression, drying and filtration, buffer vessels, gas analysis and any boosting equipment are included. Define the controls and utility boundaries explicitly; an item shown in a family illustration does not establish that it is included in the offered package.

Submit RFQ for On-site PSA Nitrogen Generation Packages

Send product, quantity, specification and destination details so the requirements can be reviewed with potential suppliers.

PDF, DOCX, XLSX, JPG, PNG or TXT. Up to 5 files, 10 MB each and 25 MB total.

Technical and RFQ References

Check common units, standards and purchasing terminology, then build a structured request for this equipment.

Oilfield Unit ConverterAPI Standards NavigatorEquipment GlossaryBuild a Structured RFQ

Related Products

AI category referenceTEG gas dehydration contactor and regeneration package in a fabrication yard

TEG Gas Dehydration Packages

TEG Gas Dehydration Packages for removal of water vapor from natural gas using triethylene glycol absorption and regeneration, with RFQ fields covering gas composition and rate, pressure and temperature, inlet water content, required water dew point, turndown, contactor type and stages, glycol concentration and circulation, regeneration heat duty, still-column and stripping-gas arrangement, flash gas, BTEX or emissions control, filtration, pumps, metallurgy, sour service, utilities, controls and performance test basis.

AI category referenceModular amine contactor and solvent regeneration skids for natural-gas treatment

Amine Gas Sweetening Units

Amine Gas Sweetening Units for removal of hydrogen sulfide and carbon dioxide from natural gas using a selected amine solvent system, with RFQ fields covering feed gas composition and contaminants, minimum normal and maximum flow, pressure and temperature, required H2S and CO2 outlet limits, solvent selection and concentration, circulation rate, absorber and regenerator design, reboiler duty, flash and acid-gas handling, filtration, corrosion control, foaming risk, metallurgy, sour service, utilities, emissions, controls and guarantee test.

Related Technical Articles

PSA Nitrogen Selection: Flow, Purity and Normal-Volume Basis

Turn separate nitrogen catalogue ranges into a structured request for one guaranteed operating point, with purity, reference state and package boundaries kept explicit.

4 min read

OILFIELD RFQ

Technical references, practical calculations and structured equipment requests for the oilfield industry.

Equipment

  • Wellhead & Pressure Control
  • Drilling & Downhole Tools
  • Mud Pump & Rig Spares
  • Sourcing & Export

Resources

  • Buyer Guides
  • Calculators & RFQ Builder
  • Equipment Reference
  • API Standards Navigator
  • FAQ
  • Procurement Glossary
  • Solutions
  • About Us
  • Contact

Contact

  • Submit RFQ online
  • China

© 2026 OILFIELD RFQ SOURCING. All rights reserved.

Privacy Policy|Terms of Service